- Fully automated, LabVIEW based test bench
- Max. DC-Link voltage: Vmax = 1,8 kV
- Maximal current pulse: Imax = 4 kA
- Maximal current slope: di/dt = 6 kA/us
- DC-link capacitance: 11,5 mF @ 1,8 kV
- Adjustable junction temperature: -25°C < Tj < +200°C
- Typical turn-ON and turn-OFF behaviour of a Si-IGBT with inductive load
- Measurement of individual modules
- TO housing with printed circuit board
- Evaluation of the DC bus connection
- Analysis of conduction losses